To solder, you need clean pipe, pipe cleaner (flux) and even heat. If the heat on the fitting and pipe is uneven, the solder will not flow all the way around. Whoever did this joint needed more even heat to get the solder to flow easily. Clean the pipe and fitting, Flux pipe and fitting.
Leaking Pipes . Some houses have plumbing lines that run through the ceiling—mainly to minimize tear-down during plumbing disasters. And just like with pipes in walls and floors, a leak may develop if the pipes freeze or the joints get loose. Only this time, the ceiling suffers from water damage.
One option is using a slip fitting. Slip fittings are rubber sleeves that can be slipped over a hairline crack in a straight pipe section. Once in place, hose clamps are secured on both sides of the fitting to compress it around the pipe and form a seal over the leak. Another common repair method involves using compression fittings.
Apply the product as follows: Small leaks: apply directly onto pipework. Burst pipes or larger leaks: apply liberally onto a cloth and wrap tightly around the pipe. Replace the cap immediately to prevent the remaining product from curing inside the tube. Spray the sealant with water to aid the curing process.
In two to five minutes before the putty dries, dunk the entire bandage roll in a bucket of water to wet it. Then, wrap the wet bandage around the pipe and putty, extending the bandage a bit beyond the putty on each side. You want to cover the area with about 12 to 15 wraps of the bandage and keep the bandage taut while you work.
Find and Repair Leaks. Before making the repair, make sure the system is turned off at the controller. Cut out the damaged section of line. Place a clamp on one of the line ends, insert a slip coupling, then tighten the clamp. Place a clamp on the second pipe end, expand the coupling while inserting the nipple into the pipe, then tighten the clamp.
How To Repair Pvc Pipe Leak At Joint. To repair a PVC pipe leak at a joint, start by turning off the water supply to the pipe. Then, cut out the affected area of the pipe using a hacksaw, making sure to leave the joint intact. Clean and dry the joint, then apply PVC primer to the joint and the outside of the cut pipe.
Interior Plumbing. To determine if the leak is from defective plumbing, turn off all faucets and appliances that use water in your home, and write down the number on the water meter. Wait three hours, and recheck the water meter. If water usage increased, it's a sign that the leak is coming from indoor plumbing.
How to fix a leaking Pipe under the Sink.How to fix a dripping Pipe joint under the Sink.This is how to fix a leak on your main inlet cold or hot water pipew
You should only use about 1/2" to 3/4" of solder to make a joint on that size; don't add more or you could just fill the pipe. Keep a dry rag to knock off excess solder and a wet rag to cool and clean the joint. Flux causes oxidation (turns green). Don't worry about burning off flux: it will take unless it's too hot.
Impure or ‘hard water’, rust particles, improper installation, etc all can cause copper unions to leak. To stop leaking, you can reseal the unions with a wrench. Plumbers use copper union joints in steel pipelines for many reasons. Copper union joints enable the pipes to be removed when they get damaged or corroded.
Once the oakum gets water against it it will swell and seal the joint, the lead keeps it in place. Chances are your existing lead joint is just fine. the cast iron institute, spokespeople for the cast iron pipe industry, will tell you the same thing. Lead joint systems were tested with a 10 foot column of water, not compressed air.
Upvote. Usually the leakage at the fittings is not a problem since you are still carrying 99% of the water away. If you want to seal up the joints you can pull the fittings apart and smear the joint area with a tar based roof patch. After several weeks you might not be able to get the joints apart without ruining the pipe.
We replaced a leaking brass T fitting that was incorrectly installed. The brass compression ring was installed to high on the fitting and eventually failed.
That looks like the entire joint has pulled out of the fitting so it is more than just a small leak. You should cut back the pipe that goes into the connector so you can assess the condition inside and then use a new length of pipe and a coupler to reattach to the fitting if it is salvageable.